Experimental Determination of Flash Point of Lubricating Oil
Abhilash P Vijayakumar, Sarath P S, Nidhin P Soman,
Aswin Vinod M K, Salman T B, D.U.S.L Deepthi, Dr.Rajesh Kanna
Abstract
Full text PDF
Index: 10.183x/A0704010103
In the Pensky-Marten's closed cup flash point test, a brass test cup is filled with a test specimen
and fitted with a cover. The sample is heated and stirred at specified ates depending on what it is that's being
tested. An ignition source is directed into the cup at regular intervals with simultaneous interruption of stirring
until a flash that spreads throughout the inside of the cup is seen. The corresponding temperature is its flash
point.
Pensky-Martens closed cup is sealed with a lid through which the ignition source can be introduced periodically.
The vapour above the liquid is assumed to be in reasonable equilibrium with the liquid. Closed cup testers give
lower values for the flash point (typically5-10 K) and are a better approximation to the temperature at which the
vapour pressure reaches the Lower Flammable Limit (LFL).
Author Keywords:- Lubricating oil, Flash point, Fire point, Temperature, Vapours.
e-ISSN: 2319-183X, p-ISSN: 2319-1821 Source Type: Journal
Original Language: English
Document Type: Article
Number of pages: 03
© Copyright 2014, All rights reserved.
A Low Rating Photovoltaic Fed Dstatcom for Harmonic
Elimination and Power Factor Correction under Non-Sinusoidal
Source
Dr. A.K. Baliarsingh, D. Mishra, M. Mantri, Dr. S. Mishra
Abstract
Full text PDF
Index: 10.183x/B0704010414
This paper proposes a photovoltaic fed improved hybrid DSTATCOM for harmonic and reactive
power compensation. The solar system is connected to the grid using a LCL passive filter with a series
connected capacitor at the front end of voltage source inverter. The series capacitor helps in reducing the dc link
voltage leading the reduction in the rating of DSTATCOM and so as also the solar system. The system is
modelled and controlled by considering the non-linearity of the system. The Fuzzy logic controller is used to
control the power flow from solar system and to maintain dc link voltage. To accomplish the arrangement robust,
switching pulses for inverter is generated using sliding approach controller.Using Simulink, the behavior of the
controllers for DC bus voltage and current control are investigated.
Author Keywords:- ....................
e-ISSN: 2319-183X, p-ISSN: 2319-1821 Source Type: Journal
Original Language: English
Document Type: Article
Number of pages: 11
© Copyright 2014, All rights reserved.
Underground Domestic Water-Tank Air Heat Exchanger
swapnil Jain, Md. Irfan Ahmed
Abstract
Full text PDF
Index: 10.183x/C0704011518
The environmental temperature variations in certain states of India like Rajasthan, Madhya
Pradesh are becoming extreme from comfort point of view. Temperature ranges from 5˚C in winter to 50˚C in
summer, against 24˚C, which is standard comfort condition for human being. These extreme temperatures are
increasing load on Heating Ventilating and Air-conditioning (HVAC) systems. These extreme conditions do not
allow atmosphere to be kept in direct communication with indoor room conditions. This lack of ventilation has a
hazardous effect on human health. Small underground water tanks of capacities ranging from 3000 liters to 5000
liters are readily available in urban areas of India due to different reasons. These water bodies can be used as
heat source or sink during winter or summer respectively. Earth Air Heat exchanger (EAHE) system is the
leading contemporary approach to reduce Air-Conditioning loads on the system. The characteristic of earth
strata at a depth of 3-4 m where temperature remains constant between 25˚C to 28˚C throughout the year by
Vikas Bansal et al. [1]. This layer of earth can be used as heat source in winter and heat sink in summer. Metal
or plastic pipes are laid at a depth of 3-4 m and in required length to remove heat from air. This heat is further
dissipated in earth mass surrounding the pipes.
Author Keywords:- Underground Domestic Water Tank Air Heat Exchanger (UDWTAHE), Earth Air Heat
Exchanger (EAHE), Cooling Capacity, Heating Ventilating and Air-conditioning (HVAC).
e-ISSN: 2319-183X, p-ISSN: 2319-1821 Source Type: Journal
Original Language: English
Document Type: Article
Number of pages: 04
© Copyright 2014, All rights reserved.
Estimating Future Sea Level Changes, Assessing Coastal
Hazards, Avoiding Misguiding Exaggerations, and
Recommending Present Coastal Management
Nils-Axel Mörner, Albert Parker, Don Easterbrook, Pamela Matlack-
Klein
Abstract
Full text PDF
Index: 10.183x/D0704011925
Hazard predictions must be anchored in very well established observational facts to be
meaningful and trustworthy. We highlight observational facts with respect to sea level changes, and to access a
recent, model-based, coastal hazard assessment for the New York City region. We conclude that available facts
strongly support a modest rise in sea level during the future centuries, and that the model-based assessment
totally fails in predicting future changes in a meaningful and realistic way.
Author Keywords:- Sea level changes; Ice melting; Coastal hazards; Coastal management.
e-ISSN: 2319-183X, p-ISSN: 2319-1821 Source Type: Journal
Original Language: English
Document Type: Article
Number of pages: 07
© Copyright 2014, All rights reserved.
A Study of Compliance of Installation Guideline With Respect To
Diesel Generators (Dg Sets) Installed In Industrial Sector
Dr.Dattatryramchandra Mane, Manoj Hanumant Misal
Abstract
Full text PDF
Index: 10.183x/E0704012631
Diesel generating units (DG Sets) are widely used in various places, Diesel generators are used to
produce electricity without connecting to a power grid. DG Sets are used for the emergency power supply as
well as it is used where electrical power is not available.
DG Set Installation requires to be carried out as per Standard Installation guidelines to ensure satisfactory
operation of the DG set. Installation guideline provides the detailed guideline for theinstallation of DG sets.
Other than technical compliance in installation, it must comply with Local / State / Central Government and all
other Statutory regulatory requirements as applicable.
Installation Guidelines provides the detailed guideline & specification which helps to install the DG Sets
properly hence quality of the DGsets can be maintained. For safe & smooth operation of DG set and increase
their efficiency which may leads to customer satisfaction.
Proper installation of DG sets can reduce several maintenance work & servicing activities.
Author Keywords:- .............
e-ISSN: 2319-183X, p-ISSN: 2319-1821 Source Type: Journal
Original Language: English
Document Type: Article
Number of pages: 06
© Copyright 2014, All rights reserved.
Assembly Line Balancing And Layout Design Of A Bicycle
Omorodion, I.I, Amiebenomo, S.O, B.O.A. Ozigi
Abstract
Full text PDF
Index: 10.183x/F0704013236
In the light of the high practical relevance of assembly line balance(ALB),it is not
astounding that a massive body of academic literature covers configuration planning of assembly system.
This paper focus is on practical application of the theorem of ALB.we look at line that is being used in
bicycle assembly by identifying the parts and procedures.the precedence diagram of part constructed and
workstation defined with cycle time of 18seconds.idle time eliminated and workstation constraint
optimized.
Author Keywords:- (workstation,task,cycle time precedence diagram).
e-ISSN: 2319-183X, p-ISSN: 2319-1821 Source Type: Journal
Original Language: English
Document Type: Article
Number of pages: 05
© Copyright 2014, All rights reserved.
A Factorial Analysis of Delay Causalities in Seismic
Reconnaissance: Implications for Petroleum Exploration In Tbe
Niger Delta
A.C. Igboanugo, S.O. Amiebenomo, B.O.A. Ozigi
Abstract
Full text PDF
Index: 10.183x/G0704013745
A field study was conducted in Benin-Sapele locale of Niger Delta to understand the role of
influencive factors identified to be associated with delay causation in seismic reconnaissance. The principal
component analysis (PCA) of Factor Analysis was used to analyse a total of 262 daily observations of time(in
hours)encountered in seismic surveys undertaken in the locale thereof. The PCA employed was effective in
achieving parsimony by reducing the factor dimension from fourteen variables to mere five platoons which were
creatively labelled: data sampling activities, logistics, permission matters, instrument integrity, and random
events. Our results suggest that human factors, terrain and logistics are the most offensive influences and that
the perceived current restiveness in the region is a backlash of unfettered exploration and roduction activities.............
Author Keywords:- Risk society, palaeogeomorphology, synstratigraphy, facies, data tectonics, ichthyofaunal
e-ISSN: 2319-183X, p-ISSN: 2319-1821 Source Type: Journal
Original Language: English
Document Type: Article
Number of pages: 09
© Copyright 2014, All rights reserved.
Effective Productivity in Construction through Labour
Management
S.Sivaraj, Dr.B.Vidivelli
Abstract
Full text PDF
Index: 10.183x/H0704014655
This paper describes the effective productivity in construction through labour management,
Construction is the second largest industry after agriculture in India. The most challenging issue in construction
industry is effective productivity and good labour performance. In construction productivity has direct
interrelationship with the three constraints there are time, cost and quality. The objectives of this research
investigate identification factors reducing and increasing productivity in construction through labour
management. The principal tool used for collection of data questionnaire survey; questionnaires for field survey.
Data for the survey are obtained through a structured questionnaire administrated to respondents in number 122.
The respondents involve 80 labours and 42 managerial peoples..............
Author Keywords:- Reducing and increasing factors, SPSS, Effective productivity through labour management.
e-ISSN: 2319-183X, p-ISSN: 2319-1821 Source Type: Journal Original Language: English
Document Type: Article
Number of pages: 10